Manual range 0.000mA 6.6mA range
00.00mA 66mA range
000.0mA 660mA range
00.00A 10A rangeuse 10A socket
c. Connect test leads in series with the load under measurement.
d. You can get reading from LCD.
NOTE:
When only the figure OL is displayed, it indicates overrange situation and the higher range has
to be selected.
When the value scale to be measured is unknown beforehand, set the range selector at the highest
position.
The maximum current of mA socket is 660mA, over-current will destroy the fuse, and will damage
the meter.
The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage
the operator.
E. Resistance Measuring
a. Connect the black test lead to the COM jack and the red test lead to theΩ jack.
b. Press to selectΩ , enter theΩ measurement. Auto range by press key, and
Manual range by press .
Manual range(connect the red lead to black leads, will display the measure range)
000.0Ω 66 range
0.000 KΩ 6KΩ range
00.00 KΩ 66KΩ range
WARNING!
When measuring in-circuit resistance, be sure the circuit under test has all power removed and
that all capacitors have discharged fully.